Change your filters on schedule
SecureAire electronic air cleaner
Hope to see her for the AC tune up this summer.
Great experience with tech Karysa...on time, efficient and knowledgeable. First call heating and cooling is now my go to.
Called on a Monday night at 630 because the heat was not working and blowing cold air. They called me back within 10 minutes got some information and explained how much it would cost. I was told someone would be here between 730-830. She was here by 7:10. She was very nice, very knowledgeable and made me feel at ease knowing that the problem would be fixed. She was great and got a few laughs in thanks to the kids. But it was an easy fix and she explained it to me in a way that I understood. I will be using this company for all future maintenance and repairs!!!!
The tech was very nice and did an amazing job. She knew what she was doing and made sure everything was running well. She also took her time as she did have 2 furnaces to clean. I would recommend your company to everyone.Again GREAT SERVICE!!
Called and came same day. Diagnosed the problem and ordered part and soon to come back and install.
No heat, found exhaust pipe to be sagging. Will add hangers.
(2) furnace inspections. Checked furnace operation to ensure it is in good, safe operating condition Checked pvc pipe condition, all ok. Checked ignition sequence, lights good, burners look good. Checked inducer .9 amps, checked blower 3.2 amps. Heat exchanger looks good. Drain location and condition of tuning, condition is acceptable. Filter condition, new, replaced with once company supplied. Thermostat operation, system cycles fine on thermostat. Furnace is in good safe operating condition at this time.
Trane furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
No heat, found dirty flame sensor giving intermittent signals. Cleaned flame sensor. Unit is now running and heating at this time.
Trane furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Trane Furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Replaced inducer motor, and performed Trane furnace tuneup. Unit is running and heating well at this time.
Found secondary heat exchanger plugged. Customer would like to get on schedule for estimate to replace furnace in the future.
No heat, inducer motor seized.
Checked thermostat, cleaned condensate trap, checked air filter, dirty, customer will replace, cleared drain lines, cleaned flame sensor, slightly chipped, recommended replacement to prevent future issues, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked propane pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
No heat, rollout switch tripped. Found heat exchanger to be plugged.
Goodman furnace inspection. Checked furnace operation to ensure it is in good, safe operating condition. Checked pvc pipe condition, all ok. Heat exchanger condition, good. Ignition sequence, lights good, burners looks good. Drain location and condition of tubing, condition is acceptable. Thermostat operation, system cycles fine on thermostat. Checked blower capacitor, within spec. Cleaned flame sensor. Furnace in good safe operating condition at this time.
Checked thermostat, checked air filter, checked blower capacitor, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Service call, furnace is running intermittently. Found filter to be completely plugged. Replaced and cycled furnace. Unit is now running and heating at this time.
Replaced inducer motor. Everything is now running and heating well.
Carrier furnace tuneup. Checked thermostat, inspected flue piping, checked air filter, checked blower capacitor, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Ruud furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
No heat, Upon arrival customer stated the furnace will run for some time, shut off and blow only cold air, then it will start to run and heat again. Cycled furnace and found error code #4 airflow problem or open fuse. Checked fuse, good. Checked air filter, very dirty, little to no light seen through. Replaced filter with one customer supplied. Checked temp rise 48 (Supply 117, Return 69). Checked gas pressure 3.9 in. w.c., adjusted to 3.5 in. w.c. Cycled unit for 25 mins without any safeties tripping. Unit is now running and heating well at this time.
Lennox furnace tuneup. Checked thermostat, checked air filter, replaced, cleared drain lines, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time. Informed customer of age and current condition of the unit.
Ruud furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Trane furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Bryant furnace tuneup. Checked thermostat, inspected flue piping, checked air filter, checked blower capacitor, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Checked thermostat, pulled and cleaned condensate trap, checked air filter, new, cleared drain lines, cleaned flame sensor, very oxidized, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, inducer motor bearings are just starting to go bad, slight noise while running, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.
Replaced thermostat under warranty.
Bryant furnace tuneup. Checked thermostat, cleaned condensate trap, checked air filter, cleared drain lines, cleaned flame sensor, checked igniter, inspected burners and heat exchanger, checked and cleaned intake pipe, checked blower and inducer motor amps, checked gas pressure, checked all wire and electrical connections, checked temperature rise, and cleaned unit. System running and heating well at this time.